Wall-mounted air conditioner Climate control accessories Page 471 Software & services Page 511 Protection rating: Note: Property rights: UL/cUL recognized, CSA Air conditioners with comfort US design patent no. D 488,480 UL Type 12/IP 54 controller may be integrated into a IR reg. design no. DM/061 967 with UL file #: SA8250 monitoring system with an optional validity for FR, IT, ES interface card 3124.200 German registered designs Configuration: (RS 232, RS 485, RS 422 and PLC no. 402 02 324 and no. 402 02 325 550 – Fully wired ready for connection interface). See page 477. Japanese registered design – Includes drilling template no. 1 187 896 280 100 T2 and assembly parts Indian registered design T 100 42 – With nano-coated condenser no. 189 953 Useful cooling capacity: 864 - 2400 BTU (253 - 703 W) Part No. with comfort controller, RAL 7035 (light grey) 3303.5001) 3303.5101) Part No. with comfort controller, Type 304 stainless steel 3303.6001) 3303.6101) Voltage V, Hz 230, 50/60 115, 60 Dimensions inches (mm) H x B x T x T2 22 x 11 x 8 x 7 (550 x 280 x 200 x 164) Useful cooling capacity QK BTU (W) Ti 131 Ta 131 2400 (703) Useful cooling capacity Q to DIN 3168 Ti 95 Ta 95 1708/2083 (500/610) 1708 (500)K BTU (W) Ti 95 Ta 122 957/1195 (280/350) 957 (280) Rated current maximum 2.6 A/2.6 A 5.7 A Starting current 5.1 A/6.4 A 11.5 A Pre-fuse T 10.0 A 10.0 A T 95 T 95 360 W/380 W 470 W Power consumption Pel to DIN 3168 i a Ti 95 Ta 122 420 W/390 W 500 W Cooling coefficient j = QK/Pel Ti 95 Ta 95 1.4 Refrigerant R134a, 6.0 oz (170 g) Maximum allowable operating pressure 406 psi (28 bar) Temperature and setting range Comfort controller - +68 to +131° F (+20 to +55° C) Environmental ratings UL Type 12 (IP 54) Duty cycle 100% Type of connection Plug-in terminal strip Weight lb (kg) 37.5 (17) External circuit 203 cfm (345 m3/h) Air displacement of fans Internal circuit 182 cfm (310 m3/h) Temperature control Comfort controller (factory setting 95° F (+35° C)) Accessories PU Page Filter mats 3 3286.300 481 Metal filters 1 3286.310 482 Door-operated switch 1 4127.010 694 Master/slave cable for comfort controller 1 3124.100 477 RiDiag II including cables for comfort controller 1 3159.100 515 Interface card for comfort controller 1 3124.200 477 Condensate hose 1 3301.610 484 1) Partial internal Mounting possible. Special voltages available by request. We reserve the right to make technical modifications. Rittal Catalog 33/Climate control Metric measurements for are exact, imperial measurements are rounded 403
rittal
To see the actual publication please follow the link above