Page 410

rittal

Wall-mounted air conditioner Climate control accessories Page 471 Software & services Page 511 Protection rating: Configuration: Additional parts needed: UL/cUL recognized, CSA – Fully wired ready for connection For installation in the door, the UL Type 12/IP 54 – Includes drilling template use of a door alignment roller 40 UL file #: SA8250 and assembly parts (4538.000) is recommended, 1580 – With nano-coated condenser see page 618. and integrated condensate evaporator. 145 245400 295 150 50 Useful cooling capacity: 8706 - 10525 BTU (2550 - 3083 W) Part No. with basic controller, RAL 7035 (light grey) 3328.100 3328.110 3328.140 3329.100 3329.110 3329.140 Part No. with basic controller, Type 304 stainless steel 3328.200 3328.210 3328.240 3329.200 3329.210 3329.240 Voltage V, Hz 230, 50/60 115, 50/60 400, 50/460, 60, 3~ 230, 50/60 115, 50/60 400, 50/460, 60, 3~ Dimensions inches (mm) H x W x D 62 x 16 x 11 (1580 x 400 x 295) Useful cooling capacity QK BTU (W) Ti 131 Ta 131 8706 (2550) 10525 (3083) 8537/9392 Useful cooling capacity QK to i 95 Ta 95 6830/8026 (2000/2350) 8537/9392 (2500/2750) (2500/2700)T DIN 3168 BTU (W) 6489/6660 Ti 95 Ta 122 4952/6771 (1450/1690) 5464/5977 (1600/1750) (1900/1950) Rated current maximum 7.5 A/9.1 A 14.7 A/17.3 A 2.8 A/3.3 A 8.6 A/10.6 A 17.0 A/22.0 A 3.7 A/3.8 A Starting current 22.0 A/26.0 A 36.0 A/39.0 A 6.8 A/7.8 A 21.0 A/21.0 A 44.0 A/42.0 A 6.8 A/7.6 A Pre-fuse T 16.0 A 25.0 A 10.0 A/10.0 A1) 16.0 A 25.0 A 10.0 A/10.0 A1) 1025 W/ 1085 W/ 930 W/ 1320 W/ 1380 W/ 1300 W/ Ti 95 Ta 95 1200 W 1250 W 1150 W 1550 W 1600 W 1500 W Power consumption Pel to DIN 3168 1130 W/ 1170 W/ 1150 W/ 1500 W/ 1550 W/ 1550 W/ Ti 95 Ta 122 1220 W 1290 W 1400 W 1880 W 1940 W 1850 W Cooling coefficient j = QK/Pel Ti 95 Ta 95 1.7 2.3 1.9 2.0 Refrigerant R134a, 33.5 oz (950 g) Maximum allowable operating pressure 406 psi (28 bar) Temperature and setting range Basic controller - +86 to +131° F (+30 to +55° C) Environmental ratings UL Type 12 (IP 54) Duty cycle 100% Type of connection Plug-in terminal strip Weight lb (kg) 145.5 (66) 160.9 (73) 147.7 (67) 152.1 (69) 167.6 (76) 154.3 (70) External circuit 377 cfm (640 m3/h) 418 cfm (710 m3/h) Air displacement of fans 3/h) 377 cfm (640 m3/h)324 cfm (550 mInternal circuit Temperature control Basic controller (factory setting 95° F (+35° C)) Accessories PU Page Filter mats 3 3286.400 481 Metal filters 1 3286.410 482 Door-operated switch 1 4127.010 694 Master/slave cable for comfort controller 1 3124.100 477 RiDiag II including cables for comfort controller 1 3159.100 515 Interface card for comfort controller 1 3124.200 477 Condensate hose 1 3301.612 484 1) Motor circuit-breaker. Special voltages available on request. We reserve the right to make technical modifications. 408 Metric measurements for are exact, imperial measurements are rounded Rittal Catalog 33/Climate control


rittal
To see the actual publication please follow the link above