Page 417

rittal

Wall-mounted UL Type 4X air conditioner Climate control accessories Page 471 Software & services Page 511 Protection rating: Configuration: Note: UL/cUL recognized, CSA – Fully wired ready for connection Air conditioner with comfort UL Type 4X – Includes drilling template controller may be integrated into a UL file #: SA8250 and assembly parts monitoring system with an optional 298 358 – With nano-coated condenser interface card 3124.20 (RS 232, RS 620 1020 Material: and integrated condensate 485, RS 422 and PLC interface). 285 238 298 Type 304 stainless steel evaporator See page 477. 405 Useful cooling capacity: 2400 - 5794 BTU (703 - 1697 W) Part No. with comfort controller 3303.5042) 3303.5142) 3304.504 3304.514 3304.544 3305.504 3305.514 3305.544 400, 50/ 400, 50/ Voltage V, Hz 230, 50/60 115, 60 230, 50/60 115, 60 230, 50/60 115, 60 460, 60, 3~ 460, 60, 3~ 24 x 11 x 12 Dimensions inches (mm) H x W x D 40 x 16 x 14 (1020 x 405 x 358) (620 x 285 x 298) Useful cooling capacity QK T 131 T 131 2400 (703) 3916 (1147) 5794 (1697) BTU (W) i a 1708/2083 T 95 T 95 1708 (500) 3415/3620 (1000/1060) 5123/5157 (1500/1510) Useful cooling capacity Q i a (500/610) K to DIN 3168 BTU (W) 956/1195 Ti 95 Ta 122 (280/350) 956 (280) 2698/2869 (790/840) 4201/4269 (1230/1250) Rated current maximum 2.6/2.6 A 5.7 A 5.4/5.0 A 10.6/11.1 A 2.8/2.9 A 6.0/6.5 A 12.1/13.6 A 2.6/2.9 A Starting current 5.1/6.4 A 11.5 A 12.0/14.0 A 26.0/28.0 A 11.5/12.7 A 22.0/24.0 A 42.0/46.0 A 12.2/11.3 A Pre-fuse T 10.0 A 10.0 A 10.0 A 16.0 A 10.0 A1) 16.0 A 20.0 A 10.0 A1) Power consumption Pel to Ti 95 Ta 95 360/380 W 470 W 700/650 W 725/680 W 580/550 W 850/1000 W 880/1050 W 800/980 W DIN 3168 Ti 95 Ta 122 420/390 W 500 W 750/710 W 780/750 W 660/680 W 1000/1160 W 1040/1200 W 960/1150 W Cooling coefficient j = T 95 T 95 1.4 1.7 1.8 1.7 1.9 QK/Pel i a Refrigerant R134a, 6.0 oz (170 g) R134a, 17.6 oz (500 g) R134a, 21.1 oz (600 g) Maximum allowable operating pressure 406 psi (28 bar) 363 psi (25 bar) Temperature and setting range Comfort controller - +68 to +131° F (+20 to +55° C) Environmental ratings UL Type 4X (IP 66) Duty cycle 100% Type of connection Plug-in terminal strip Weight lb (kg) 55.1 (25) 108.2 (49) 119.0 (54) 110.2 (50) 112.4 (51) 123.5 (56) 114.6 (52) Material Type 304 stainless steel Air displacement of External circuit 203 cfm (345 m3/h) 530 cfm (900 m3/h) 530 cfm (900 m3/h) fans Internal circuit 182 cfm (310 m3/h) 353 cfm (600 m3/h) 471 cfm (800 m3/h) Temperature control Comfort controller (factory setting 95° F (+35° C)) Accessories PU Page Door-operated switch 1 4127.010 694 Master/slave cable for comfort 1 3124.100 – 3124.100 477 controller RiDiag II including cables for comfort 1 3159.100 515 controller Interface card for comfort controller 1 3124.200 477 Condensate hose 1 3301.610 3301.612 484 1) Motor circuit breaker. 2) Internal condensate evaporator not included. Special voltages and technical modifications available on request. Rittal Catalog 33/Climate control Metric measurements for are exact, imperial measurements are rounded 415


rittal
To see the actual publication please follow the link above