Page 509

rittal

Data Center Container DCC Fire protection: Climate control – preconfigured data center types. − Fire alarm/gas extinguisher − Fire protection, internal direct free cooling: Ask for the Rittal Data Center system (Novec 1230) panels: F30, optionally F90 − Available with 23900 and 34144 Container project planning form. − Access systems, access door based on DIN 4102/EN1363, BTU (7 and 10 kW) units. Up to Within just a few days, you will (keyboard, code card) component-tested 3 units can be integrated receive an initial quote. Bayed − Monitoring and management − Targeted cooling via aisle containers, higher cooling (CMC, RiZone) Duct system: containment outputs e.g. using LCP technology − Type: Hard duct DN200 or more than seven racks – we Detailed drawings: − Dimensions of packing space: Power distribution: would be happy to design your Available at www.rittal-corp.com 5 x 5 inches (120 x 120 mm) − Infeed: CEE connector 125 A, own individual data center 3-phase/N/PE, 400 V/50 Hz container. Additional container Sizes: Raised floor: − Enclosure dimensions, sizes, including ISO compliant − ISO shipping container available. − Substructure type: H x W x D inches (mm) dimensions, are available. − Additional dimensions available. Control room 80 x 32 x 24 (2000 x 600 x 400) − Number of slotted plates Optional: Photo shows a configuration with dependent on number of racks Note on standard and − Up to seven 19” (482.6 mm) equipment not included in the − Total raised height: customized versions: IT racks with power supply base part number 12 inches (300 mm) There is a standard range of − UPS, with up to 15 minutes models available with 12 autonomy Version R7A R7B R7C R7D R14A R14B R14C R14D R20A R20B R20C R20D Height x Width x Depth inches (mm) 128 x 118 x 238 (3250 x 3000 x 6055) Usable area ft2 (m2) 163 (15.2) Part No. Project planning on request 23900 23900 23900 23900 47800 47800 47800 47800 68288 68288 68288 68288 Cooling capacity BTU (kW) (7) (7) (7) (7) (14) (14) (14) (14) (20) (20) (20) (20) Redundancy cooling 1+1 1+1 1+1 1+1 2+1 2+1 2+1 2+1 2+1 2+1 2+1 2+1 177 177 177 177 157 157 157 157 157 157 157 157 Available area inches (mm) (racks, UPS, DET-AC) (4500) (4500) (4500) (4500) (4000) (4000) (4000) (4000) (4000) (4000) (4000) (4000) Heavy-duty raised floor Plug-and-play power distribution Hard ducts 2 x DN200 Security door WK2 Optional items UPS (uninterruptible power supply) DET-AC XL fire alarm/extinguisher system Max. no. of racks 42 U (24 inches (600 mm) wide) 7 6 7 6 7 6 6 5 7 6 6 5 Max. no. of racks 42 U (32 inches (800 mm) wide) 5 4 5 4 5 4 4 4 5 4 4 4 Higher racks (47 U) Rack power supply (PSM, PDM) Monitoring package (CMC) Security door WK3 Additional hard ducts Metal sun shade Standard Option Rittal Catalog 33/IT infrastructure Metric measurements for are exact, imperial measurements are rounded 507


rittal
To see the actual publication please follow the link above