Page 573

rittal

Walls Isolator door locking Flange mount Main door locking Part No. disconnect locking For TS 8611.310 For safety locking of enclosures and bayed suites in conjunction with up to 200A disconnect Note: switches and up to 400A circuit breaker operating 8611.310 includes interlock activator mechanisms.1) (4912.000 see below). Included with master – Allen Bradley 1494 F-M1/P1/S1 and flange mount disconnect cabinet. 1) May work with some circuit braker operating 140 U-K-FCX04 mechanisms greater than 400A. – Square D 9422 A1 Non-FMD door locking 1 Interlock activator, – ITE Siemens Max-Flex series/FHOH installation in enclosure (only available in the USA) 3 4 3 4 3 with main switch – General Electric TDA Type 1 and 2 2 Adjacent door locking, – Moeller NZM-XSHGVR 12-NA 2 2 1 2 installation in adjacent enclosure To complete the assembly you must order 3 Interconnecting rod 4911.000 (see below) and the required interconnecting rods for bayed suites. 4 Connection component (included in the supply of .25 (7.1) interconnecting rod) FMD door locking 5 FMD main door lock 4.3) .562 (1 6 Interlock activator, 3 4 3 4 3 5 installation in the main enclosure (included in the 1 (25.4) ) 2 7/16 (61.9 supply of the FMD main 1) 19. Cut-out for main switch door lock position 5).6222 4 11/16 (1 1 (25.4) .5 (12.7) Door interlocking for Part No. bayed suites Interlock activator 4912.000 For extending the door lock of commercially available main switches to TS bayed suites. Adjacent door locking Part No. Adjacent door cannot be opened until the main door has been opened. 1 Door 4911.000 The main switch can be positioned anywhere 2 Door 4911.100 in the suite; its function is independent from the door hinge position. Subsequent locking of the For enclosure width PU Part No. 1 2 adjacent doors in the suite is possible: They are inches (mm) thus automatically included in locking operation. 24 (600) 10 4916.000 32 (800) 10 4918.000 1 Interlock activator (Fitted in the enclosure with main switch and 47 (1200) 10 4920.000 additionally in every fourth adjacent enclosure) 2 Adjacent door locking (Installation in adjacent enclosure) 3 Interconnecting rods To extend locking from the main enclosure to the adjacent enclosures of a bayed suite. 3 An interconnecting rod corresponding to the width of the enclosure is required for each adjacent enclosure. Rittal Catalog 33/System accessories Metric measurements for are exact, imperial measurements are rounded 571


rittal
To see the actual publication please follow the link above