Wall-mounted air conditioner Climate control accessories Page 471 Software & services Page 511 Protection rating: Note: Property rights: UL/cUL recognized, CSA Air conditioners with comfort US design patent no. D 488,480 UL Type 12/IP 54 controller may be integrated IR reg. design no. DM/061 967 with UL file #: SA8250 into a monitoring system with an validity for FR, IT, ES optional interface card 3124.200 German registered designs Configuration: (RS 232, RS 485, RS 422 and PLC no. 402 02 324 and no. 402 02 325 550 – Fully wired ready for connection interface). See page 477. Japanese registered design – Includes drilling template no. 1 187 896 280 125 235 and assembly parts Indian registered design 280 155 45 – With nano-coated condenser no. 189 953 Useful cooling capacity: 2663 BTU (780 W) Part No. with comfort controller, RAL 7035 (light grey) 3361.500 3361.510 3361.5401) Part No. with comfort controller, Type 304 stainless steel 3361.600 3361.610 3361.6401) Voltage V, Hz 230, 50/602) 115, 602) 400, 2~, 50/602) Dimensions inches (mm) H x W x D 22 x 11 x 11 (550 x 280 x 280) Useful cooling capacity Q BTU (W) Ti 131 Ta 131 2663 (780)K T 95 T 95 2561/2664 (750/780) 2561 (750) 2561/2664 (750/780) Useful cooling capacity QK to DIN 3168 BTU (W) Ti 95 Taa 122 1742/1844 (510/540) 1742 (510) 1742/1844 (510/540)i Rated current maximum 2.3 A/2.4 A 5.3 A 1.2 A/1.4 A Starting current 5.6 A/5.6 A 12.0 A 3.1 A/3.3 A Pre-fuse T 10 A 10 A 10 A T 95 T 95 480 W/555 W 570 W 480 W/550 W Power consumption Pel to DIN 3168 i a Ti 95 Ta 122 530 W/640 W 670 W 530 W/640 W Cooling coefficient j = QK/Pel Ti 95 Ta 95 1.5 Refrigerant R134a, 9.9 oz (280 g) Maximum allowable operating pressure 406 psi (28 bar) Temperature and setting range Comfort controller - +68 to +131° F (+20 to +55° C) Environmental ratings UL Type 12 (IP 54) Duty cycle 100% Type of connection Plug-in terminal strip Weight lb (kg) 48.5 (22) External circuit 283 cfm (480 m3/h) Air displacement of fans (unimpeded air flow) Internal circuit 353 cfm (600 m3/h) Temperature control Comfort controller (factory setting 95° F (+35° C)) Accessories PU Page Filter mats 3 3286.300 481 Metal filters 1 3286.310 482 Door-operated switch 1 4127.010 694 Master/slave cable for comfort controller 1 3124.100 477 RiDiag II including cables for comfort controller 1 3159.100 515 Interface card for comfort controller 1 3124.200 477 Condensate hose 1 3301.608 484 1) External transformer Ø 5 x 3" (126 x 65 mm) deep which must be mounted by the end customer. 2) T maximum = 125° F (52° C)/60 Hz. a Special voltages available upon request. We reserve the right to make technical modifications. Rittal Catalog 33/Climate control Metric measurements for are exact, imperial measurements are rounded 405
rittal
To see the actual publication please follow the link above