Page 408

rittal

Wall-mounted air conditioner Climate control accessories Page 471 Software & services Page 511 Protection rating: Property rights: UL/cUL recognized, CSA German registered design UL Type 12/IP 54 no. 402 02 325 UL file #: SA8250 IR reg. design no. DM/062 557 with validity for FR, IT, ES Configuration: Indian registered design 950 – Fully wired ready for connection no. 190 269 – Includes drilling template Japanese registered design 400 260 155105 50 210 and assembly parts no. 1 187 905 – With nano-coated condenser Useful cooling capacity: 3916 - 5794 BTU (1147 - 1697 W) Part No. with basic controller, RAL 7035 (light grey) 3304.100 3304.110 3304.140 3305.100 3305.110 3305.140 Part No. with basic controller, Type 304 stainless steel 3304.200 3304.210 3304.240 3305.200 3305.210 3305.240 Voltage V, Hz 230, 50/60 115, 50/60 400, 50/460, 60, 3~ 230, 50/60 115, 50/60 400, 50/460, 60, 3~ Dimensions inches (mm) H x W x D 37 x 16 x 10 (950 x 400 x 260) Useful cooling capacity QK BTU (W) Ti 131 Ta 131 3916 (1147) 5794 (1697) Useful cooling capacity QK to DIN 3168 Ti 95 Ta 95 3415/3620 (1000/1060) 5123/5157 (1500/1510) BTU (W) Ti 95 Ta 122 2698/2869 (790/840) 4201/4269 (1230/1250) 4.8 A/ 9.5 A/ 2.5 A/ 5.4 A/ 11.0 A/ 2.3 A/ Rated current maximum 4.4 A 10.0 A 2.6 A 6.0 A 12.5 A 2.6 A 12.0 A/ 26.0 A/ 11.5 A/ 22.0 A/ 42.0 A/ 12.2 A/ Starting current 14.0 A 28.0 A 12.7 A 24.0 A 46.0 A 11.3 A 10.0 A/ 16.0 A/ 10.0 A/ 16.0 A/ 20.0 A/ 10.0 A/ Pre-fuse T 1) 16.0 A 20.0 A 10.0 A1)10.0 A16.0 A10.0 A 700 W/ 725 W/ 580 W/ 850 W/ 880 W/ 800 W/ T 95 T 95 i a 650 W 680 W 550 W 1000 W 1050 W 980 W Power consumption Pel to DIN 3168 750 W/ 780 W/ 660 W/ 1000 W/ 1040 W/ 960 W/ Ti 95 Ta 122 710 W 750 W 680 W 1160 W 1200 W 1150 W Cooling coefficient j = QK/Pel Ti 95 Ta 95 1.4 1.7 1.8 1.7 1.9 Refrigerant R134a, 11.4 oz (325g) R134a, 17.6 oz (500 g) R134a, 21.2 oz (600 g) Maximum allowable operating pressure 363 psi (25 bar) Temperature and setting range Basic controller - +86 to +131° F (+30 to +55° C) Environmental ratings UL Type 12 (IP 54) Duty cycle 100% Type of connection Plug-in terminal strip Weight lb (kg) 86.0 (39) 97.0 (44) 88.2 (40) 90.3 (41) 101.4 (46) 92.6 (42) External circuit 530 cfm (900 m3/h) Air displacement of fans 3/h) 471 cfm (600 m3/h)353 cfm (600 mInternal circuit Temperature control Basic controller (factory setting +95° F (+35° C)) Accessories PU Page Filter mats 3 3286.400 481 Metal filters 1 3286.410 482 Door-operated switch 1 4127.010 694 Master/slave cable for comfort controller 1 3124.100 477 RiDiag II including cables for comfort controller 1 3159.100 515 Interface card for comfort controller 1 3124.200 477 Condensate hose 1 3301.612 484 1) Motor circuit-breaker. Special voltages available on request. We reserve the right to make technical modifications. 406 Metric measurements for are exact, imperial measurements are rounded Rittal Catalog 33/Climate control


rittal
To see the actual publication please follow the link above