Liquid Cooling Package Accessories for climate control Page 471 Chillers for IT cooling Page 454 Server enclosures Page 134 Benefits: the cooling output can be – Touchscreen display may be Application and mode of – Maximum energy efficiency adapted to actual requirements retrofitted operation: thanks to EC fan technology – The box-type plug-in fan units The LCP draws in the air at the and IT-based control are configurable as n+1 Monitoring of all system-relevant sides at the rear of the server – Minimal pressure loss at the redundancy parameters such as: enclosures, cools it using high air end, which in turn minimises – Standard 3-phase connection – Server air intake temperature performance compact impellers, the power consumption of the for electrical redundancy – Server waste air temperature and blows the cooled air fans – With redundant temperature – Water inlet/return temperature back into the front part of the – Optimum adaptability thanks sensor integrated at the air – Water flow server enclosure at the sides. to dynamic, continuous control end as standard – Cooling output of the cold water volume flow – The separation of cooling and – Fan speed Protection rating: – By using high water inlet rack prevents water from – Leakage IP 40 to IEC 60 529 temperatures, the proportion penetrating the server enclosure – Optional sensors of indirect free cooling is – Up to 60 kW cooling output on – Direct connection of the unit Color: increased, which in turn a footprint of just 0.36 m2 via SNMP/Ethernet RAL 7035 light grey/Sand Texture reduces operating costs – The low weight means a minimal – Integration into RiZone Black – Thanks to six modular, load area box-type plug-in fan units, TopTherm LCP Rack CW and DX Design CW CW CW DX Cooling medum Water Refrigerant R410a Part No. RAL 7035 light grey 3311.130 3311.230 3311.260 3311.110 Sand Texture Black 3311.135 3311.235 3311.265 – Rated operating voltage V, Hz 230, 1~, 50/60, 400, 3~, 50/60 80 x 12 x 40 80 x 12 x 48 80 x 12 x 48 80 x 12 x 48 Dimensions inches (mm) H x W x D (2000 x 300 x 1000) (2000 x 300 x 1200) (2000 x 300 x 1200) (2000 x 300 x 1200) Usable U 42 42 42 42 Useful cooling output BTU (kW) Up to 102364 (30) Up to 102364 (30) Up to 204728 (60) Up to 34121 (10) Duty cycle 100% Electrical connection Connection cable Linear fan control Temperature control Two way control valve – Fans may be exchanged with the system operational EC fan Also required Packs of Page Condenser unit 1 – – – 3311.310 461 Accessories Fan module, RAL 7035 1 3311.010 – Fan module, Sand Texture Black 1 4967.527 – Touchscreen display, colored 1 3311.030 461 Connection hose, top/bottom 1 3311.040 462 Rittal Catalog 33/Climate control Metric measurements for are exact, imperial measurements are rounded 457
rittal
To see the actual publication please follow the link above