Page 460

rittal

Liquid Cooling Package Accessories for climate control Page 471 Chillers for IT cooling Page 454 Server enclosures Page 134 Aisle containment Page 456 Benefits: requirements Monitoring of all system-relevant Protection rating: – Maximum energy efficiency – The box-type plug-in fan units parameters such as: IP 40 to IEC 60 529 thanks to EC fan technology are configurable as n+1 – Server air intake temperature and IT-based control redundancy – Server waste air temperature Application and mode of – Minimal pressure loss at the – Standard 3-phase connection – Water inlet/return temperature operation: air end, which minimizes the for electrical redundancy – Water flow The LCP is designed for siting power consumption of the fans – With redundant temperature – Cooling output within a bayed enclosure suite. – Optimum adaptability from sensor integrated at the air end – Fan speed The hot air is drawn in from the dynamic, continuous control as standard – Leakage room or hot aisle at the rear of of the cold water volume flow – The separation of cooling and – Optional sensors the device and expelled at the – By using high water inlet rack prevents water from – Direct connection of the unit via front into the cold aisle after temperatures, the proportion penetrating the server enclosure SNMP/Ethernet cooling. The LCP achieves of indirect free cooling is – Up to 60 kW cooling output on – Integration into RiZone maximum performance and increased, which in turn a footprint of just 0.36 m2 efficiency in conjunction with reduces operating costs – The low weight means a minimal Color: Rittal cold aisle containment. With – Thanks to six modular, box-type load area RAL 7035 light grey this product, a raised floor is not plug-in fan units, the cooling – Touchscreen display may be Sand Texture Black necessary. output can be adapted to actual retrofitted TopTherm LCP Inline CW and DX Design CW CW CW DX Cooling medum Water Refrigerant R410a Part No. RAL 7035 light grey 3311.530 3311.560 3311.540 3311.210 Sand Texture Black 3311.535 3311.565 3311.545 – Rated operating voltage V, Hz 230, 1~, 50/60, 400, 3~, 50/60 80 x 12 x 48 80 x 12 x 48 80 x 12 x 48 80 x 12 x 48 Dimensions inches (mm) H x W x D (2000 x 300 x 1200) (2000 x 300 x 1200) (2000 x 300 x 1200) (2000 x 300 x 1200) Usable U 42 42 42 42 Useful cooling output BTU (kW) Up to 102364 (30) Up to 204728 (60) Up to 102364 (30) Up to 34121 (10) Front alignment Protruding Flush Duty cycle 100% Electrical connection Connection cable Linear fan control Temperature control Two-way control valve – Fans may be exchanged with the system operational EC fan Also required Packs of Page Condenser unit 1 – – 3311.310 461 Accessories Front cover, RAL 7035/Sand Texture Black 1 3311.060/9967.528 3311.060/9967.528 3311.060/9967.528 3311.060/9967.528 – Fan module, RAL 7035/Sand Texture Black 1 3311.010/9967.527 3311.010/9967.527 3311.020/9967.530 3311.010/9967.527 – Touchscreen display, colored 1 3311.030 3311.030 3311.030 3311.030 461 Connection hose, top/bottom 1 3311.040 3311.030 3311.030 3311.030 462 458 Metric measurements for are exact, imperial measurements are rounded Rittal Catalog 33/Climate control


rittal
To see the actual publication please follow the link above